Prevent Exit During Register Access
The core clock turns off during L1 substates. The register interface needs the core clock to respond to register access requests. Therefore, an L1- substate exit is triggered by default while accessing registers. You can change this behavior with the Low Power Debug and Control Register 1/ Disable Autonomous L1.x Exit upon Reg Access field in the local management space. This field is mostly helpful for debugging.