Configuring the Dynamic Clock Multiplexers

You configure the dynamic clock multiplexers in the Interface Designer. Expand Device Setting > Clock/Control Configuration and then click the multiplexer for the bottom, left, right, or top.

Table 1. Global Buffer Configuration
Option Choices Description
Core Clock n Pin Name User defined Specify a clock from the core that drives the global buffer. You can use up to four.
Enable Dynamic Mux 0
Enable Dynamic Mux 7
On or off Turn on this option to enable the dynamic mulplexer.
The clock multiplexers (static and dynamic) are numbered from 0 to 7. The dynamic ones are 0 and 7.
Dynamic Clock Mux Select [1:0] Bus Name User defined Specify the bus that controls the dynamic multiplexer.
Dynamic Clock Pin Name User defined Specify the clock name that drives the core RTL design.
Dynamic Clock Input n List of sources1 or None Choose the clock source.
Unassigned indicates that you have not yet used that resource.
Choose None if you want to leave an input unassigned. A clock source must be assigned to the dynamic clock multiplexer input 0.
Independently Connect to Core On or off Enable this option if you want the clock source to also be available to the core.
1 Refer to the Driving the Global Network topic in the data sheet for the list of available clock sources.