Configuring the Dynamic Clock Multiplexers
You configure the dynamic clock multiplexers in the Interface Designer. Expand and then click the multiplexer for the bottom, left, right, or top.
| Option | Choices | Description |
|---|---|---|
| Core Clock n Pin Name | User defined | Specify a clock from the core that drives the global buffer. You can use up to four. |
| Enable Dynamic Mux 0 Enable Dynamic Mux 7 |
On or off | Turn on this option to enable the dynamic mulplexer. The
clock multiplexers (static and dynamic) are numbered from 0 to
7. The dynamic ones are 0 and 7. |
| Dynamic Clock Mux Select [1:0] Bus Name | User defined | Specify the bus that controls the dynamic multiplexer. |
| Dynamic Clock Pin Name | User defined | Specify the clock name that drives the core RTL design. |
| Dynamic Clock Input n | List of sources1 or None | Choose the clock source. Unassigned indicates that you have not yet used that
resource. Choose None if you want to
leave an input unassigned. A clock source must be assigned to
the dynamic clock multiplexer input 0. |
| Independently Connect to Core | On or off | Enable this option if you want the clock source to also be available to the core. |
1 Refer to the Driving the Global Network topic
in the data sheet for the list of available clock sources.