Machine Interrupt Pending Register (mip): 0x344

The mip register is a 12-bit read/write register containing information on pending interrupts.

11 10 9 8 7 6 5 4 3 2 1 0
MEIP Reserved SEIP Reserved MTIP Reserved STIP Reserved MSIP Reserved SSIP Reserved
Bits Field Description Single/Multi-Core w/FPU w/MMU
0 Reserved Reserved. N/A N/A N/A
1 SSIP Supervisor software interrupt pending. N/A N/A Read/Write
2 Reserved Reserved. N/A N/A N/A
3 MSIP Machine software interrupt pending. Read/Write Read/Write Read/Write
4 Reserved Reserved. N/A N/A N/A
5 STIP Supervisor timer interrupt pending. N/A N/A R/W
6 Reserved Reserved. N/A N/A N/A
7 MTIP Machine timer interrupt pending. Read Read Read
8 Reserved Reserved. N/A N/A N/A
9 SEIP Supervisor external interrupt pending. N/A N/A Read/Write
10 Reserved Reserved. N/A N/A N/A
11 MEIP Machine external interrupt pending. Read Read Read