Ti375 I/O Banks

Efinix FPGAs have input/output (I/O) banks for general-purpose usage. Each I/O bank has independent power pins. The number and voltages supported vary by FPGA and package.

Some I/O banks are merged at the package level by sharing VCCIO pins, these are called merged banks. Merged banks have underscores (_) between banks in the VCCIO name (e.g., 1B_1C means VCCIO for bank 1B and 1C are connected). Some of the banks in a merged bank may not have available user I/Os in the package. The following table lists banks that have available user I/Os in a package.

Table 1. I/O Banks by Package
Package GPIO Type I/O Banks Voltage (V) Dynamic Voltage Support DDIO Support Merged Banks
N484 HSIO 2B, 2C, 2D, 2E, 4B, 4C, 4D 1.2, 1.35, 1.5, 1.8 All 2A_2B_2C, 4A_4B
HVIO BR0, BR3, TR1 1.8. 2.5, 3.0, 3.3 Yes All BR3_BR4
C529 HSIO 2A, 2B, 2C, 2D, 2E, 4B, 4C, 4D 1.2, 1.35, 1.5, 1.8 All 4A_4B
HVIO BL2, BL3, BR0, BR3, TL1, TL5, TR0, TR1, TR2 1.8. 2.5, 3.0, 3.3 Yes All BR3_BR4,
TL1_TL5
BL2_BL3
N900 HSIO 2A, 2B, 2C, 2D, 2E, 4A, 4B, 4C, 4D 1.2, 1.35, 1.5, 1.8 All
HVIO BL2, BL3, BR0, BR3, BR4, TL0, TL1, TL5, TR1 1.8. 2.5, 3.0, 3.3 Yes All TL1_TL5
N1156 HSIO 2A, 2B, 2C, 2D, 2E, 4A, 4B, 4C, 4D 1.2, 1.35, 1.5, 1.8 All
HVIO BL0, BL1, BL2, BL3, BR0, BR1, BR3, BR4, TL0, TL1, TL5, TR0, TR1, TR2, TR3, TR5 1.8. 2.5, 3.0, 3.3 Yes All TL1_TL5
Notice: Refer to the Ti375 Pinout for information on the I/O bank assignments.