Ethernet XGMII Common Properties Tab

The settings in this tab apply to all lanes in the same quad.

Table 1. Common Properties Tab: Config Sub-Tab Settings
Parameter Choices Notes
Common Instance Name User defined Default: cmn_inst1. This field defines the prefix that is applied to all common signals.
Reference Clock Frequency (MHz) User defined Default: 156.250
Reference Clock Source External You must use an external clock.
Clock CMN_REFCLK0 Defaults to CMN_REFCLK0. Block Editor shows the name of the resource that you should use for this clock.
Enable 50 Ω to ground on-die termination for REFCLK0 On, off Default: on. Indicate whether to use on-die termination for the reference clock.
Table 2. Common Properties Tab: APB Sub-Tab
Parameter Selection Notes
APB Clock Pin Name User defined Specify the pin name.
Invert APB Clock Pin On, off Default: off. Indicate whether to invert the clock signal.
Pin and bus names User defined Define the APB pin names. Efinix recommends using the default names.
Table 3. Common Properties Tab: Error And Status Sub-Tab Settings
Parameter Selection Notes
PHY Ready Pin Name User defined Define the pin name. Efinix recommends using the default name.